Inductive reactance calculator
Online calculator for formulas used in electronic circuit design and electrical engineering.
Basic electric calculations:
Ohm's Law,
Ohm's Law with power,
DC power,
AC real power,
LC resonant frequency,
Capacitor charging/discharging,
Capacitive reactance,
Capacitive current + reactive power,
Capacitor energy,
Capacitor Δ energy,
RC discharging,
Inductor square pulse,
Inductive reactance,
Inductive current + reactive power,
Inductor energy,
2 parallel resistors,
3 parallel resistors,
2 parallel inductors,
2 series capacitors,
System bandwidth,
Bandwidth ↔ rise time,
frequency ↔ period
Wire and winding calculations:
Calculate Inductive reactance: 4.7mH, 125kHz, mΩ
This calculation can calculate the inductive reactance X
L of an inductor knowing its inductance and the frequency.
You can also calculate the inductance knowing the desired reactance and frequency, or calculate the frequency knowing the inductive reactance and inductance.
X
L = 2 π f L
Enter any 2 values, the 3rd one will be calculated:
Standard EIA Decade Values of inductors - decade 1 to 10 mH
| E6 | E12 | E24 |
1.0 mH
1.5 mH
2.2 mH
3.3 mH
4.7 mH
6.8 mH
| 1.0 mH, 1.2 mH
1.5 mH, 1.8 mH
2.2 mH, 2.7 mH
3.3 mH, 3.9 mH
4.7 mH, 5.6 mH
6.8 mH, 8.2 mH
| 1.0 mH, 1.1 mH, 1.2 mH, 1.3 mH
1.5 mH, 1.6 mH, 1.8 mH, 2.0 mH
2.2 mH, 2.4 mH, 2.7 mH, 3.0 mH
3.3 mH, 3.6 mH, 3.9 mH, 4.3 mH
4.7 mH, 5.1 mH, 5.6 mH, 6.2 mH
6.8 mH, 7.5 mH, 8.2 mH, 9.1 mH
|
Other inductance decades:
100 - 1000 pH,
1 - 10 nH,
10 - 100 nH,
100 - 1000 nH,
1 - 10 uH,
10 - 100 uH,
100 - 1000 uH,
1 - 10 mH,
10 - 100 mH,
100 - 1000 mH,
1 - 10 H,
10 - 100 H,
Some common standard frequencies:
Inductive reactance formula says:
•The inductive reactance (X
L) of a 4.7mH (four point seven millihenrys) inductor at 125kHz (one hundred and twenty-five kilohertz) is 3.691371367968kΩ (three point six nine one three seven one three six seven nine six eight kiloohms).
•For a 3.691371367968kΩ (three point six nine one three seven one three six seven nine six eight kiloohms) inductive reactance at 125kHz (one hundred and twenty-five kilohertz), you need a 4.7mH (four point seven millihenrys) inductor.
•A 4.7mH (four point seven millihenrys) inductor would have a 3.691371367968kΩ (three point six nine one three seven one three six seven nine six eight kiloohms) reactance at 125kHz (one hundred and twenty-five kilohertz) frequency.
This is a simple online calculator for formulas used in electronic engineering and design.
This online calculator is for reference only. I do not guarantee it to work correctly. You use this at your own risk only.